Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Hum Brain Mapp ; 44(10): 3998-4010, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37162380

RESUMO

There has been growing attention on the effect of COVID-19 on white-matter microstructure, especially among those that self-isolated after being infected. There is also immense scientific interest and potential clinical utility to evaluate the sensitivity of single-shell diffusion magnetic resonance imaging (MRI) methods for detecting such effects. In this work, the performances of three single-shell-compatible diffusion MRI modeling methods are compared for detecting the effect of COVID-19, including diffusion-tensor imaging, diffusion-tensor decomposition of orthogonal moments and correlated diffusion imaging. Imaging was performed on self-isolated patients at the study initiation and 3-month follow-up, along with age- and sex-matched controls. We demonstrate through simulations and experimental data that correlated diffusion imaging is associated with far greater sensitivity, being the only one of the three single-shell methods to demonstrate COVID-19-related brain effects. Results suggest less restricted diffusion in the frontal lobe in COVID-19 patients, but also more restricted diffusion in the cerebellar white matter, in agreement with several existing studies highlighting the vulnerability of the cerebellum to COVID-19 infection. These results, taken together with the simulation results, suggest that a significant proportion of COVID-19 related white-matter microstructural pathology manifests as a change in tissue diffusivity. Interestingly, different b-values also confer different sensitivities to the effects. No significant difference was observed in patients at the 3-month follow-up, likely due to the limited size of the follow-up cohort. To summarize, correlated diffusion imaging is shown to be a viable single-shell diffusion analysis approach that allows us to uncover opposing patterns of diffusion changes in the frontal and cerebellar regions of COVID-19 patients, suggesting the two regions react differently to viral infection.


Assuntos
COVID-19 , Substância Branca , COVID-19/diagnóstico por imagem , COVID-19/patologia , Imagem de Tensor de Difusão , Estudos de Viabilidade , Substância Branca/diagnóstico por imagem , Substância Branca/ultraestrutura , Lobo Frontal/diagnóstico por imagem , Lobo Frontal/ultraestrutura , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso
2.
Front Med (Lausanne) ; 9: 861680, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35755067

RESUMO

As the COVID-19 pandemic devastates globally, the use of chest X-ray (CXR) imaging as a complimentary screening strategy to RT-PCR testing continues to grow given its routine clinical use for respiratory complaint. As part of the COVID-Net open source initiative, we introduce COVID-Net CXR-2, an enhanced deep convolutional neural network design for COVID-19 detection from CXR images built using a greater quantity and diversity of patients than the original COVID-Net. We also introduce a new benchmark dataset composed of 19,203 CXR images from a multinational cohort of 16,656 patients from at least 51 countries, making it the largest, most diverse COVID-19 CXR dataset in open access form. The COVID-Net CXR-2 network achieves sensitivity and positive predictive value of 95.5 and 97.0%, respectively, and was audited in a transparent and responsible manner. Explainability-driven performance validation was used during auditing to gain deeper insights in its decision-making behavior and to ensure clinically relevant factors are leveraged for improving trust in its usage. Radiologist validation was also conducted, where select cases were reviewed and reported on by two board-certified radiologists with over 10 and 19 years of experience, respectively, and showed that the critical factors leveraged by COVID-Net CXR-2 are consistent with radiologist interpretations.

3.
Sci Rep ; 12(1): 3376, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35232991

RESUMO

Prostate cancer (PCa) is the second most common cancer in men worldwide and the most frequently diagnosed cancer among men in more developed countries. The prognosis of PCa is excellent if detected at an early stage, making early screening crucial for detection and treatment. In recent years, a new form of diffusion magnetic resonance imaging called correlated diffusion imaging (CDI) was introduced, and preliminary results show promise as a screening tool for PCa. In the largest study of its kind, we investigate the relationship between PCa presence and a new variant of CDI we term synthetic correlated diffusion imaging (CDI[Formula: see text]), as well as its performance for PCa delineation compared to current standard MRI techniques [T2-weighted (T2w) imaging, diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) imaging] across a cohort of 200 patient cases. Statistical analyses reveal that hyperintensity in CDI[Formula: see text] is a strong indicator of PCa presence and achieves strong delineation of clinically significant cancerous tissue compared to T2w, DWI, and DCE. These results suggest that CDI[Formula: see text] hyperintensity may be a powerful biomarker for the presence of PCa, and may have a clinical impact as a diagnostic aid for improving PCa screening.


Assuntos
Meios de Contraste , Neoplasias da Próstata , Estudos de Coortes , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
4.
Med Phys ; 48(4): 1815-1822, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33417726

RESUMO

PURPOSE: Cardiac relaxometry techniques, particularly T1 mapping, have recently gained clinical importance in various cardiac pathologies. Myocardial T1 and extracellular volume are usually calculated from manual identification of left ventricular epicardial and endocardial regions. This is a laborious process, particularly for large volume studies. Here we present a fully automated relaxometry framework (FASTR) for segmental analysis of T1 maps (both native and postcontrast) and partition coefficient (λ). METHODS: Patients (N = 11) were imaged postacute myocardial infarction on a 1.5T clinical scanner. The scan protocol involved CINE-SSFP imaging, native, and post-contrast T1 mapping using the Modified Look-Locker Inversion (MOLLI) recovery sequence. FASTR consisted of automatic myocardial segmentation of spatio-temporally coregistered CINE images as an initial guess, followed by refinement of the contours on the T1 maps to derive segmental T1 and λ. T1 and λ were then compared to those obtained from two trained expert observers. RESULTS: Robust endocardial and epicardial contours were achieved on T1 maps despite the presence of infarcted tissue. Relative to experts, FASTR resulted in myocardial Dice coefficients (native T1: 0.752 ± 0.041; postcontrast T1: 0.751 ± 0.057) that were comparable to interobserver Dice (native T1: 0.803 ± 0.045; postcontrast T1: 0.799 ± 0.054). There were strong correlations observed for T1 and λ derived from experts and FASTR (native T1: r = 0.83; postcontrast T1: r = 0.87; λ: r = 0.78; P < 0.0001), which were comparable to inter-expert correlation coefficients (native T1: r = 0.90; postcontrast T1: r = 0.93; λ: r = 0.80; P < 0.0001). CONCLUSIONS: Our fully automated framework, FASTR, can generate accurate myocardial segmentations for native and postcontrast MOLLI T1 analysis without the need for manual intervention. Such a design is appealing for high volume clinical protocols.


Assuntos
Infarto do Miocárdio , Miocárdio , Meios de Contraste , Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
5.
Front Med (Lausanne) ; 8: 821120, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35242769

RESUMO

Medical image analysis continues to hold interesting challenges given the subtle characteristics of certain diseases and the significant overlap in appearance between diseases. In this study, we explore the concept of self-attention for tackling such subtleties in and between diseases. To this end, we introduce, a multi-scale encoder-decoder self-attention (MEDUSA) mechanism tailored for medical image analysis. While self-attention deep convolutional neural network architectures in existing literature center around the notion of multiple isolated lightweight attention mechanisms with limited individual capacities being incorporated at different points in the network architecture, MEDUSA takes a significant departure from this notion by possessing a single, unified self-attention mechanism with significantly higher capacity with multiple attention heads feeding into different scales in the network architecture. To the best of the authors' knowledge, this is the first "single body, multi-scale heads" realization of self-attention and enables explicit global context among selective attention at different levels of representational abstractions while still enabling differing local attention context at individual levels of abstractions. With MEDUSA, we obtain state-of-the-art performance on multiple challenging medical image analysis benchmarks including COVIDx, Radiological Society of North America (RSNA) RICORD, and RSNA Pneumonia Challenge when compared to previous work. Our MEDUSA model is publicly available.

6.
Front Med (Lausanne) ; 8: 729287, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35360446

RESUMO

The COVID-19 pandemic continues to rage on, with multiple waves causing substantial harm to health and economies around the world. Motivated by the use of computed tomography (CT) imaging at clinical institutes around the world as an effective complementary screening method to RT-PCR testing, we introduced COVID-Net CT, a deep neural network tailored for detection of COVID-19 cases from chest CT images, along with a large curated benchmark dataset comprising 1,489 patient cases as part of the open-source COVID-Net initiative. However, one potential limiting factor is restricted data quantity and diversity given the single nation patient cohort used in the study. To address this limitation, in this study we introduce enhanced deep neural networks for COVID-19 detection from chest CT images which are trained using a large, diverse, multinational patient cohort. We accomplish this through the introduction of two new CT benchmark datasets, the largest of which comprises a multinational cohort of 4,501 patients from at least 16 countries. To the best of our knowledge, this represents the largest, most diverse multinational cohort for COVID-19 CT images in open-access form. Additionally, we introduce a novel lightweight neural network architecture called COVID-Net CT S, which is significantly smaller and faster than the previously introduced COVID-Net CT architecture. We leverage explainability to investigate the decision-making behavior of the trained models and ensure that decisions are based on relevant indicators, with the results for select cases reviewed and reported on by two board-certified radiologists with over 10 and 30 years of experience, respectively. The best-performing deep neural network in this study achieved accuracy, COVID-19 sensitivity, positive predictive value, specificity, and negative predictive value of 99.0%/99.1%/98.0%/99.4%/99.7%, respectively. Moreover, explainability-driven performance validation shows consistency with radiologist interpretation by leveraging correct, clinically relevant critical factors. The results are promising and suggest the strong potential of deep neural networks as an effective tool for computer-aided COVID-19 assessment. While not a production-ready solution, we hope the open-source, open-access release of COVID-Net CT-2 and the associated benchmark datasets will continue to enable researchers, clinicians, and citizen data scientists alike to build upon them.

7.
Sensors (Basel) ; 20(5)2020 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-32164378

RESUMO

Prostate cancer is the most commonly diagnosed cancer in North American men; however, prognosis is relatively good given early diagnosis. This motivates the need for fast and reliable prostate cancer sensing. Diffusion weighted imaging (DWI) has gained traction in recent years as a fast non-invasive approach to cancer sensing. The most commonly used DWI sensing modality currently is apparent diffusion coefficient (ADC) imaging, with the recently introduced computed high-b value diffusion weighted imaging (CHB-DWI) showing considerable promise for cancer sensing. In this study, we investigate the efficacy of ADC and CHB-DWI sensing modalities when applied to zone-level prostate cancer sensing by introducing several radiomics driven zone-level prostate cancer sensing strategies geared around hand-engineered radiomic sequences from DWI sensing (which we term as Zone-X sensing strategies). Furthermore, we also propose Zone-DR, a discovery radiomics approach based on zone-level deep radiomic sequencer discovery that discover radiomic sequences directly for radiomics driven sensing. Experimental results using 12,466 pathology-verified zones obtained through the different DWI sensing modalities of 101 patients showed that: (i) the introduced Zone-X and Zone-DR radiomics driven sensing strategies significantly outperformed the traditional clinical heuristics driven strategy in terms of AUC, (ii) the introduced Zone-DR and Zone-SVM strategies achieved the highest sensitivity and specificity, respectively for ADC amongst the tested radiomics driven strategies, (iii) the introduced Zone-DR and Zone-LR strategies achieved the highest sensitivities for CHB-DWI amongst the tested radiomics driven strategies, and (iv) the introduced Zone-DR, Zone-LR, and Zone-SVM strategies achieved the highest specificities for CHB-DWI amongst the tested radiomics driven strategies. Furthermore, the results showed that the trade-off between sensitivity and specificity can be optimized based on the particular clinical scenario we wish to employ radiomic driven DWI prostate cancer sensing strategies for, such as clinical screening versus surgical planning. Finally, we investigate the critical regions within sensing data that led to a given radiomic sequence generated by a Zone-DR sequencer using an explainability method to get a deeper understanding on the biomarkers important for zone-level cancer sensing.


Assuntos
Imagem de Difusão por Ressonância Magnética , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Algoritmos , Área Sob a Curva , Árvores de Decisões , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Masculino , Análise de Regressão , Sensibilidade e Especificidade , Máquina de Vetores de Suporte
8.
Front Med (Lausanne) ; 7: 608525, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33425953

RESUMO

The coronavirus disease 2019 (COVID-19) pandemic continues to have a tremendous impact on patients and healthcare systems around the world. In the fight against this novel disease, there is a pressing need for rapid and effective screening tools to identify patients infected with COVID-19, and to this end CT imaging has been proposed as one of the key screening methods which may be used as a complement to RT-PCR testing, particularly in situations where patients undergo routine CT scans for non-COVID-19 related reasons, patients have worsening respiratory status or developing complications that require expedited care, or patients are suspected to be COVID-19-positive but have negative RT-PCR test results. Early studies on CT-based screening have reported abnormalities in chest CT images which are characteristic of COVID-19 infection, but these abnormalities may be difficult to distinguish from abnormalities caused by other lung conditions. Motivated by this, in this study we introduce COVIDNet-CT, a deep convolutional neural network architecture that is tailored for detection of COVID-19 cases from chest CT images via a machine-driven design exploration approach. Additionally, we introduce COVIDx-CT, a benchmark CT image dataset derived from CT imaging data collected by the China National Center for Bioinformation comprising 104,009 images across 1,489 patient cases. Furthermore, in the interest of reliability and transparency, we leverage an explainability-driven performance validation strategy to investigate the decision-making behavior of COVIDNet-CT, and in doing so ensure that COVIDNet-CT makes predictions based on relevant indicators in CT images. Both COVIDNet-CT and the COVIDx-CT dataset are available to the general public in an open-source and open access manner as part of the COVID-Net initiative. While COVIDNet-CT is not yet a production-ready screening solution, we hope that releasing the model and dataset will encourage researchers, clinicians, and citizen data scientists alike to leverage and build upon them.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...